FLUXUS G809
The ultrasonic gas flow meter for operation in hazardous areas
The FLUXUS G809 is FLEXIM's dual channel ultrasonic clamp-on flow meter for bi-directional flow measurement of gases in hazardous areas ( ATEX, IECEx Zone 1 and FM Class I, Div. 1 / 2 approved).
With its flameproof housing and the corrosion resistant transducers residing inside the rugged VARIOFIX C mounting fixture, ensuring a permanent contact pressure and high mechanical stability, the FLUXUS G809 series is perfectly suited for every demanding industrial application.
The FLUXUS G809 gas flow meter allows for an inherently bi-directional gas flow measurement of operational and standard volume flows. As the transducers are mounted on the outside of the pipe wall, the system does not suffer from wear and tear or clogging, can't be a risk for leaks and will not cause any pressure drops inside the pipe.
Due to its matched and paired transducers as well as the internal temperature compensation (compliant to ANSI/ASME) the measurement system is drift free and zero stable ensuring accurate readings. The gas flow meter can be applied at inner pipe diameters ranging from 6 mm up to 2100 mm (with no limitations on pipe wall thickness or material) and media temperatures from -40°C up to 100°C.
With up to two measurement channels, the FLUXUS G809 permanent gas flow meter can also be applied to difficult measurement points and is completely unaffected by gas density, viscosity and composition as well as temperature and pressure. Even wet gas up to Liquid Volume Fractions of 5% can be measured.
优点
- Bi-directional flow measurement of liquids and gases in FM Class I, Div. 1 and ATEX / IECEx Zone 1 areas
- Very cost effective: No pipe works, No process shut-downs, Virtually maintenance-free
- Matched, paired and wet calibrated flow transducers (traceable certification to national standards)
- Excellent zero point stability and drift-free
- Wide turndown ratio
- Independent of pipe size, material, operating pressure and gas composition
- High tolerance to entrained solids and gas wetness
- Free of wear, tear and abrasion
- Not prone to clogging or corrosion
- No pressure loss or source of potential leaks and fugitive emissions
技术参数
FLUXUS G809
Permanent Gas Flow Meter for Hazardous Areas
- 工作温度
- -30°C...60°C
- 防护等级
- IP66 (Transmitter) Coating for Offshore usage
- 测量量
- volumetric flow rate, mass flow rate, flow velocity
- 可用危险区域等级
- ATEX, IECEx Zone 1, FM Class I, Div. 1
- 输出
- 4 (various combinations of current, binary, Modbus and HART are available)
- 通信协议
- HART, Modbus
- 介质温度
- -40°C ... +100°C
- 管径范围
- 10 mm ... 2100 mm
- 流速范围
- 0,01 ... 35 m/s
- 测量精度
- ±0.5 % of reading ±0.01 m/s, field calibrated ±1 .. 3 % of reading ±0.01 m/s
- 重复性
- ±0.15% of reading ± 0.01 m/s
- 其他注意事项
- 240V or 24V DC power supply version of the transmitter available